Solar Inverters

SE 20KHB-T3-LV

SE 20KHB-T3-LV is a three-phase hybrid inverter rated at 20 kW, for solar generation and battery-connected power systems.

Power20 kW
ProtectionIP65
Request a Quote

KNOW YOUR SYSTEM

Product overview

Its 3 MPPT tracker configuration and the PV input limits below support planning of the solar strings. Match the battery voltage range and charge/discharge limits to the selected storage system.

Check the AC output, backup operating limits and communication interfaces together when designing the installation. The tables retain model-specific ratings and distinguish optional functions from standard equipment.

  • No. of MPPT trackers: 3
  • Battery Voltage Range/V: 40–60
  • Cooling Method: Smart Cooling
  • Communication Interfaces: RS485/CAN(for BMS),RS485(for Meter),DRMs,CAN(for parallel),2*DO,2*DI,USB(for Wi-Fi/LAN,Optional)

Technical specifications

Model-specific data from the supplied product records and specification sheets. Values marked for confirmation are not included in the headline ratings.

Product & application
ParameterSpecification
ModelSE 20KHB-T3/LV
PhaseThree-phase
Product NameThree Phase Hybrid Inverter 20kW
Working Modehybrid
Battery & energy
ParameterSpecification
Battery Charge/Discharge Current (A)380 / 380
Battery Rated Voltage (V)48
Battery TypeLithium-ion/Lead-acid
Battery Voltage Range (V)40–60
Max Charge/Discharge Power (kW)20 / 20
No. of Battery Input2 (one terminal set limits charge/discharge to 250 A)
Built-in Battery Breaker400 A, optional
PV input
ParameterSpecification
MPPT Voltage Range (V)160–980
Max PV Open Circuit Voltage (V)1000
Max Short Circuit Current per MPPT (A)30/30/30
Maximum PV Input Power (kW)40
No. of MPPT trackers3
No. of Strings per MPP Tracker1/1/1
Startup Voltage (V)120
PV SwitchYes
Max Input Current per MPPT (A)20/20/20
Max PV Usable Power (kW)30
AC output & backup
ParameterSpecification
AC Rated Output Power (kW)20
Max AC Output Apparent Power (kVA)22
Max AC Output Current (A)3*33.3
Max Grid Passthrough Current (A)45
Max Single Phase Power (kW)8.5
Nominal AC Frequency (Hz)50/60
Nominal AC Output Current (A)3×30.3 / 3×29 / 3×27.8
Nominal AC Voltage (V)220V/380V;230V/400V,240V/415V 3W+N+PE
Power Factor>0.99@rated power(Adjustable 0.8 LD-0.8 LG)
Transfer Time (ms)<10ms(Typical)
THDi (%)<3 at rated power
Backup THDv (%)<3 with 100% resistive load
Backup Nominal AC Power (kW)20
Backup Peak Output150% for 10 s
Generator Max Input Power (kW)30
Performance & protection
ParameterSpecification
European Efficiency (%)97
IP Ingress Protection Rating65
Max Efficiency (%)97.6
Protection FeaturesAnti-Islanding, DC Switch, Insulation Detection, Overcurrent, Overvoltage, PV Reverse Polarity, Residual Current, Surge
Protection CategoryClass I
Surge ProtectionDC Type II / AC Type II
AFCI 2.0 / RSDOptional
Controls & communication
ParameterSpecification
Communication InterfacesRS485/CAN(for BMS),RS485(for Meter),DRMs,CAN(for parallel),2*DO,2*DI,USB(for Wi-Fi/LAN,Optional)
DisplayLED+LCD
Mechanical & environment
ParameterSpecification
Cooling MethodSmart Cooling
Dimensions (W*H*D) (mm)460*742*266
Humidity (%)0–100
Max Operation Altitude (m)4,000m(>2,000m derating)
MountingWall bracket
Operating Temperature (℃)−25 to 60 (>45 derating)
Weight (kg)46.5
Packing & logistics
ParameterSpecification
Pcs for 20FT (pcs)100
Pcs for 40FT (pcs)210
Pcs for 40HQ (pcs)252
Source-listed standards & warranty
ParameterSpecification
Warranty (years)5 years; 10 years optionalSource-listed term; confirm coverage and options with the quotation.
Safety standards (datasheet)IEC/EN 62109-1/-2Listed in the product source. This entry is not a verified model-specific certificate.
EMC standards (datasheet)IEC/EN 61000-6-1/-2/-3/-4; IEC/EN 62920Listed in the product source. This entry is not a verified model-specific certificate.
Grid codes (datasheet)IEC 61727/62116; IEC 60068; IEC 61683; EN50549-1/10; CEI 0-21Listed in the product source. This entry is not a verified model-specific certificate.

Documentation checks

Source and confirmation
The supplied acoustic report names this model. Results apply to its test setup and conditions, not every installation.
Read the specification guide

Source documents

Build your system

Let’s talk about your project.

Tell us what you are building. We will help you find the information and product options you need.

Request a Quote

Request a Quote

Tell us what you are building. We will help you find the information and product options you need.